高压巡检

   高压消防水泵巡检控制设备
      高压水泵巡检控制设备,一般应用在采用高压电机驱动的水泵巡检过程中。 随着我国工业水平的快速发展,一些大型企业消防泵站大多选用了6-10KV的中压电机作为水泵的驱动动力。因此,对于大功率、高电压的电动机,配备专用的高压启动设备----高压巡检柜 ,成为了一种需求。北京东方神龙环保设备制造有限公司对于高压电机水泵控制与自动巡检系统,已具有成熟可靠的方案和生产能力,并取得高压联络柜检验报告和谐波检验报告。高压巡检柜保证长期处于非运行状态的消防水泵得到日常巡检维护,确保消防水泵的可靠运行。
      目前,我公司在高压消防泵联动控制柜采用采用带储能式的高压真空断路器配合KYN28柜实现高压消防泵的联动控制,既可以实现各种远程启泵,也可实现就地启泵同时还能满足GB50974-2014中消防机械应急启泵的要求。

      生产制造依据标准及规范:
      GB50974- 2014《消防给水及消火栓系统技术规范》条文“11控制与操作”之规定,
      GB16927.1-1997《高电压试验技术 第一部分:一 般试输要求》;

      GB3906 2006 《3.6- 40 .5KV金属封闭开关设备和控制设备》;

      GB/T11022- 1999《高压开关设备和控制没备标准的共同技术要求》;

      IEC60694: 1996《高压开关设备和控制设备的通用技术要求》。


      High pressure fire pump inspection control equipment
      High pressure water pump inspection control equipment is generally used in the inspection process of water pump driven by high pressure motor. With the rapid development of China's industrial level, most of the fire pump stations in some large enterprises choose 6-10KV medium voltage motor as the driving power of the pump. Therefore, for high-power, high-voltage motors, equipped with special high-voltage starting equipment - high-voltage inspection cabinet, has become a demand. Beijing Dongfang Shenlong environmental protection equipment manufacturing Co., Ltd. has a mature and reliable scheme and production capacity for the control and automatic inspection system of high-voltage motor water pump, and has obtained the inspection report of high-voltage contact cabinet and harmonic inspection report. The high-pressure inspection cabinet ensures the daily inspection and maintenance of the fire pump in the non operating state for a long time, and ensures the reliable operation of the fire pump.
     At present, our company adopts high-pressure vacuum circuit breaker with energy storage type and kyn28 cabinet to realize the linkage control of high-pressure fire pump in the linkage control cabinet of high-pressure fire pump, which can not only realize the remote start of various pumps, but also realize the local start of pumps and meet the requirements of emergency start of fire engines in gb50974-2014.
     Production and manufacturing standards and specifications:
Article "11 control and operation" of GB50974-2014 technical code for fire water supply and hydrant system,
Gb16927.1-1997 high voltage test technology Part 1: General test requirements;
GB3906 2006 3.6-40.5KV metal enclosed switchgear and control equipment;
GB / t11022-1999 common technical requirements of standards for high voltage switchgear and control equipment;
Iec60694: 1996 general technical requirements for high voltage switchgear and control equipment.